You are offline — AutoTools still works from your device.
Lesson 2 of 4 30 min

Starting and Cranking Systems

The starter motor’s high current demand, the control circuit that engages it, and the voltage drops that prevent a healthy engine from cranking.

In this lesson
  • Estimate starter current from power and system voltage
  • Explain the starter solenoid and control circuit
  • Calculate the effect of cable resistance on cranking voltage

The starter motor converts electrical energy into the mechanical torque needed to turn the engine. It draws a very large current for a short period, so the battery, cables, connections and ground path all matter. A starter that turns slowly is often limited by the circuit rather than by the motor itself.

I = P ÷ V
Approximate current draw for a given mechanical power and system voltage; real motors also have efficiency and starting transients.
Worked example

Starter current estimate

Problem. A starter is rated at 1.2 kW on a 12 V system. Estimate its current draw.

Solution. I = P ÷ V = 1200 ÷ 12 = 100 A. Real cranking current is higher during the initial inrush and lower once the engine turns, so this is an order-of-magnitude estimate.

Cable voltage drop

At cranking current, even a small cable resistance produces a significant voltage drop. The voltage available at the starter is the battery voltage minus the drops in the positive cable, the ground cable and the connections.

V_drop = I × R_circuit
Total voltage drop in the cranking path; include positive cable, ground cable and connection resistance.
Worked example

Cranking voltage at the starter

Problem. A starter draws 100 A through a circuit with a total resistance of 0.02 Ω. What voltage is lost in the circuit?

Solution. V_drop = 100 × 0.02 = 2 V. If the battery holds 12 V during the attempt, the starter sees about 10 V.

  • The solenoid engages the pinion and closes the high-current starter contact.
  • The control circuit may include a relay and a clutch or neutral safety switch.
  • Cable and connection resistance matter most at cranking current.
  • A slow crank can be caused by the battery, cables, connections, ground or starter.
Cranking current can cause burns and can ignite fuel vapour. Disable ignition or fuel delivery according to the manufacturer’s procedure before any test that turns the engine.
Key points.
  • Starter current is high and brief.
  • I = P/V gives an order-of-magnitude estimate.
  • V_drop = I × R explains slow cranking.
  • The solenoid and control circuit must also be checked.
Practice

Worked example

A 1.5 kW starter on 12 V draws roughly 125 A. Through a 0.03 Ω path the drop is 3.75 V, so the starter may see only about 8.25 V from a 12 V battery.