Electric potential at a point is the electric potential energy per unit positive charge, V = W/q, measured in volts. Potential is a scalar field defined relative to a chosen reference point and is related to the electric field by E = −∇V.
Learning objectives
- Define electric potential and explain why it is measured in volts.
- Distinguish electric potential from potential difference and potential energy.
- Calculate potential from work and charge.
- Relate potential difference to electric field strength in a uniform field.
Progressive explanation
Start with the plain-language idea, then move into the engineering detail. Each level stands on its own, so you can stop at the depth you need.
Beginner The core idea
We almost never measure absolute potential. Instead we measure a difference between two points, which is what a voltmeter does. The negative terminal of a car battery is normally used as the 0 V reference, so we describe the positive terminal as 12 V. The choice of reference does not change any physical result.
Intermediate How it behaves in a circuit
The potential difference between two points is the work done per unit charge moving between them, and the electric field points in the direction of decreasing potential. In a uniform field, the potential falls linearly with distance along the field, giving ΔV = E × d. A voltmeter measures this difference and draws only a tiny current because of its high input resistance.
Advanced Limits, assumptions, engineering detail
Potential energy is only defined for a charge configuration, whereas potential belongs to the field itself. In a capacitor, energy is stored in the field, with energy density ½εE². This distinction matters when fields change in time and when electromagnetic energy propagates through space rather than along conductors.
Formulas and variables
Units of measurement
| Quantity | Symbol | Unit |
|---|---|---|
| Electric potential | V | volt (V) |
| Potential energy | W | joule (J) |
| Charge | q | coulomb (C) |
| Electric field | E | volt per metre (V/m) |
Worked examples
Potential from energy per charge
Problem. Moving 0.50 C between two points requires 30 J of work. What is the potential difference?
Solution. V = W / q = 30 J / 0.50 C = 60 V.
Potential of a point charge
Problem. Calculate the potential 0.30 m from a point charge of 2.0 µC, with zero potential at infinity.
Solution. V = kQ/r = 8.99 × 10⁹ × 2.0 × 10⁻⁶ / 0.30 = 17,980 / 0.30 ≈ 59,933 V.
Practical applications
- Nodal analysis of circuits
- Battery and cell terminal voltages
- Capacitor energy storage
- Electrostatic shielding and equipotential bonding
Automotive applications
Automotive electrics use the chassis as the reference potential, conventionally called ground or 0 V. Every module measures voltages relative to this reference, so a poor chassis connection shifts the reference and corrupts sensor readings. Voltage-drop testing of grounds is therefore part of systematic electrical diagnosis.
Industrial applications
Industrial distribution systems define a reference and distributed equipotential bonding so that touch voltages stay controlled. In three-phase systems, phase-to-neutral and phase-to-phase potentials are different values, and the same physical insulation may be stressed differently depending on the earthing arrangement of the installation.
Measurement procedure
- A voltmeter measures potential difference, so both probes must contact the two points of interest.
- The meter’s high input resistance means it draws very little current, but it still loads very high-impedance circuits.
- Ground references can differ between equipment; measure between the actual points rather than assuming earth is one node.
- For safety, select a meter and leads with a voltage and category rating suitable for the circuit.
Common mistakes
- Confusing potential with potential energy: potential is energy per unit charge, measured in volts.
- Believing potential has an absolute value: only differences are measurable and physically meaningful.
- Treating potential as a vector: it is a scalar and adds algebraically with sign.
- Assuming a voltmeter reads the same voltage regardless of where its reference probe is placed.
Safety considerations
- Treat a conductor at a potential different from earth as live until proved otherwise.
- Use test leads and meters rated for the installation category and voltage involved.
- Do not rely on a single meter indication; verify on a known good source and re-verify after the measurement.